LAC Health Logo
Account
Cart
HomeWarehouse
Solutions
LeadershipLocationsCareersFAQ
Press ReleasesArticles
Browse Knowledge Base
Browse All Standards
Browse Documentation
Guidelines
Commitments
Toolkit Terms of AgreementReturns & Refund PolicyTerms and ConditionsRx Agreement PolicyPayments PolicyPrivacy Policy
CollectionsCategoryBrands
ToolsContact us
HomeQuote
Warehouse
Cart
Account

Loading...

AI-Powered Healthcare Solutions

Transform Your Healthcare Supply Chain with Intelligent Automation

LAC Health leverages cutting-edge AI and machine learning to optimize procurement, predict demand, and streamline your healthcare operations. Partner with us to unlock next-generation efficiency.

Contact Business Development[email protected]

500k+

SKUs Available

AI

Demand Forecasting

97%

On-Time Delivery

24hrs

Response Time

LAC Health Logo

A healthcare business solutions firm building next generation procurement platforms for mission-critical supply chain operations.

Follow Us

FacebookTwitterPinterestLinkedInTikTokYouTube

Company Info

  • About
  • Leadership
  • Careers
  • Contact

Policies

  • Terms
  • Privacy
  • Returns
  • Payments

Resources

  • Knowledge Base
  • Medical Standards
  • Documentation
  • Tools

Quick Links

  • Request Quote
  • Support
  • Chat
  • Warranty

© 1997–2025 LAC Health. All rights reserved.

[email protected]•+1 (844) 794-6091•10304 Eaton Pl Suite 100, Fairfax, VA 22030
Sitemap•Accessibility
Home/Uncategorized/B Braun 4252535-02 - Introcan Safety IV Catheter 20G x 1.25 FEP (S), EACH
SKU
LAC1006987
Category
Uncategorized

FAQs

What is the retail return or exchange policy on this item?

Unopened retail units are eligible for refund or exchange within 30 days of receipt. Initiate a return through your order history or call our retail support team, and we will email a prepaid return label within one business day.

How fast will my order arrive and which warehouse will ship it?

Orders release within 24 hours and ship from the LAC warehouse closest to your ZIP (Chicago, Dallas, or Los Angeles). Most retail customers receive delivery in 1–3 business days with full tracking updates.

Can I qualify for discounts or auto-refill pricing?

Yes. Add two or more cases, enroll in Subscribe & Save, or share your monthly usage and our retail team will apply bundle pricing instantly—no contracts required.

Which payment methods are supported for retail checkout?

We accept all major credit and debit cards, digital wallets (Apple Pay, Google Pay), Buy Now Pay Later, and HSA/FSA cards. ACH and wire options are also available for larger storefront purchases.

What kind of support do I get after purchasing?

Retail customer care is available 7 days a week by phone, chat, or email. Need product guidance, reorder help, or claim assistance? Text or call 844-LAC-6091 and we will respond within an hour.

Clinical-grade SKU

B Braun 4252535-02 - Introcan Safety IV Catheter 20G x 1.25 FEP (S), EACH

Product Description B Braun 4252535-02 – Introcan Safety IV Catheter 20G x 1. 25 FEP (S), EACH B Braun 4252535-02 Introcan Safety IV Catheter Although safety devices were introduced over a decade ago, preventing needlestick injuries continues to be a major concern. With the B.

SKU LAC1006987Ships from Chicago in 1-2 business daysSerialized lot traceability
Request a quote (Valid for next 2 hours)Talk to supply desk
Product Description

B Braun 4252535-02 – Introcan Safety IV Catheter 20G x 1.25 FEP (S), EACH

B Braun 4252535-02 Introcan Safety IV Catheter

Although safety devices were introduced over a decade ago, preventing needlestick injuries continues to be a major concern. With the B. Braun Introcan Safety IV Catheter, you are protected by a truly passive safety device that is activated automatically and cannot be by-passed. No extra steps are required to ensure healthcare worker and patient safety.

This easy-to-use safety IV catheter incorporates separate needle and catheter flashback – Double Flashback technology – that gives you the added confidence of successful placement every time. The sharp needle features a Universal Bevel geometry that allows a wider choice of insertion angles, which is designed to make the catheter easy to adapt to and venipuncture more comfortable for patients. And with less plastic content than other safety IV catheters, you can potentially reduce storage space and medical waste.

Raise your facilitys standard of care and choose the B. Braun Introcan Safety IV Catheter to:

  • Reduce Needlestick Injuries: recent studies1,2 confirm that passive safety designs offer 2-3 times better protection against accidental needlesticks than active designs. INS Standards also recommend the use of passive safety devices.
  • Promote First Stick Success: the innovative Double Flashback technology allows separate confirmation of both needle and catheter placement, which can result in better first stick success and greater clinician confidence. New technology in our 24 Ga. catheters is designed to speed flashback of blood to help confirm placement in patients. Research also shows Introcan Safety is easier to introduce into the vein compared to the leading IV catheter.
  • Improve Patient Comfort: the sharp needle features a Universal Bevel that is designed for a wider choice of insertion angles and produces less tearing.
  • Ensure Best Practices: the passive safety design ensures that the safety mechanism is always activated and prevents re-insertion of the stylet. Additionally, a recent study shows Introcan Safety results in less blood exposure to staff than catheters featuring spring-retraction of the needle.
  • Help the Environment: lighter, more compact design can potentially lower shipping, storage and waste disposal costs.

Introcan Safety IV Catheter


B Braun 4252535-02 Introcan Safety IV Catheter Insertion Guide

Preparation

  • Select and prepare site according to facility protocol.
  • Completely remove the paper from the packaging.
  • Remove protective cover by holding at each end, then pull straight apart.
  • DO NOT ROTATE CATHETER PRIOR TO INSERTION
  • Confirm catheter hub is seated tightly against flashback chamber.

Perform insertion

  • Hold skin taut, insert catheter at optimal insertion angle.
  • Visualize first flashback in flashback chamber to confirm needle entry in the vessel.
  • Upon first flashback visualization, LOWER and advance the needle and catheter together approx 3mm or 1/8 in. to ensure catheter tip is in the vessel.

Thread catheter

  • Holding needle still, advance the catheter off needle and visualize second flash within the catheter to confirm catheter is in the vessel.
  • After confirmation, continue advancing catheter off the needle into the vessel.
  • Release tourniquet.

Occlude vessel and stabilize catheter hub

Remove needle from catheter

  • With hub stabilized, swiftly remove needle straight out from hub.
  • The passive safety shield automatically covers the needle bevel.
  • Properly discard needle into sharps container

Connect and secure catheter

  • Immediately CONNECT and TIGHTEN the accessory device to the catheter hub.
  • Stabilize and dress the site per facility protocol.

Device Characteristics of B Braun 4252535-02 Introcan Safety IV Catheter

What MRI safety information does the labeling contain? Labeling does not contain MRI Safety Information
Device required to be labeled as containing natural rubber latex or dry natural rubber (21 CFR 801.437): No
Device labeled as “Not made with natural rubber latex”: Yes
For Single-Use: Yes
Prescription Use (Rx): Yes
Over the Counter (OTC): No
Kit: No
Combination Product: No
Human Cell, Tissue or Cellular or Tissue-Based Product (HCT/P): No
Purchase summaryReady to ship

$505.20

Accepted payment methods

Volume pricing, managed services, and consignment programs available through LAC Health procurement.

Contract & blanket PO support

GHX • Workday • SAP integrations

Checkout now
FedEx
DHL
UPS
USPS

Delivery & Shipping

Check ETA for your dock in seconds.

Free standard shipping on orders over $75

Express and white-glove freight options available

Partner with LAC Health

Let’s architect a resilient supply programme together.

Invite our procurement strategists into your planning room and we’ll deliver a clinically-aligned sourcing roadmap—complete with compliance, telemetry, and logistics tuned to your realities.

Schedule a strategy callExplore deployment playbooks
LAC Marketplace

Customer reviews

What procurement leaders and clinical teams are saying after deploying this SKU.

Write a review
St. Vincent’s supply deskVerified purchase

Seamless onboarding, documentation arrived within the first shipment, and replenishment cadence locked in during week one. Strong visibility and support end-to-end.

Methodist perioperativeVerified purchase

Arrived cold-chain validated with serialized lots pre-registered in our ERP. Teams aligned rapidly thanks to LAC’s transition kit and consultative launch.